Previous  Next  Search
Empire Pipeline, Inc.
FERC Gas Tariff
Original Volume No. 1

Original Sheet No. 144

                        GENERAL TERMS AND CONDITIONS


5.    MEASUREMENT AND MEASUREMENT EQUIPMENT (Cont'd.)


            The operator, for purposes of this section, shall be the owner 
            of the equipment referenced herein, or the agent of such owner, 
            or such other person as the parties may agree in writing.

            If, upon any test, any measuring equipment is found to be in 
            error, such errors shall be taken into account in a practical 
            manner in computing the deliveries. If the resultant aggregate 
            error in the computed receipts or deliveries is not more than 
            two percent (2%), then previous receipts or deliveries shall be 
            considered accurate. All equipment shall, in any case, be 
            adjusted at the time of test to record correctly. If, however, 
            the resultant aggregate error in computing receipts or 
            deliveries exceeds two percent (2%), at a recording 
            corresponding to the average hourly rate, of Gas flow rate for 
            the period since the last preceding test, the previous 
            recordings of such equipment shall be corrected to zero error 
            for any period which known definitely or agreed upon, but in 
            case the period is not known definitely or agreed upon, such 
            correction shall be for a period extending over one-half of the 
            time elapsed since the date of the last test.


      5.4   In the event any measuring equipment is out of service, or is 
            found registering inaccurately and the error is not determinable 
            by test, previous recordings of receipts or deliveries through 
            such equipment shall be determined as follows; provided, 
            however, that the correction period shall not exceed 
            one (1) year:

            (a)  by using the registration of any check meter or meters if 
                 installed and accurately registering, or in the absence of 
                 (a);

            (b)  by correcting the error if the percentage of error is 
                 ascertainable by calibration, special test or mathematical 
                 calculation, or in the absence of both (a) and (b) then;

            (c)  by estimating the quantity of receipt or delivery based on 
                 receipts or deliveries during preceding periods under 
                 similar conditions when the meter was registering 
                 accurately.

Issued by: R. C. Kraemer, Vice President
Issued on: August 1, 2008                     Effective on: December 10, 2008
Previous  Next  Search